ROC800-Series RTU devices are vulnerable to an authentication bypass, which could allow an attacker to gain unauthorized access to data or control of the device and cause a denial-of-service condition.
Emerson DeltaV Distributed Control System (DCS) has insufficient verification of firmware integrity (an inadequate checksum approach, and no signature). This affects versions before 14.3 of DeltaV M-series, DeltaV S-series, DeltaV P-series, DeltaV SIS, and DeltaV CIOC/EIOC/WIOC IO cards.
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC.
The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations.
Emerson OpenBSI through 2022-04-29 mishandles credential storage. It is an engineering environment for the ControlWave and Bristol Babcock line of RTUs. This environment provides access control functionality through user authentication and privilege management. The credentials for various users are stored insecurely in the SecUsers.ini file by using a simple string transformation rather than a cryptographic mechanism.
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. TELNET on port 18550 provides access to a root shell via hardcoded credentials. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350.
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. FTP has hardcoded credentials (but may often be disabled in production). This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350.
Emerson OpenBSI through 2022-04-29 uses weak cryptography. It is an engineering environment for the ControlWave and Bristol Babcock line of RTUs. DES with hardcoded cryptographic keys is used for protection of certain system credentials, engineering files, and sensitive utilities.
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. WIOC SSH provides access to a shell as root, DeltaV, or backup via hardcoded credentials. NOTE: this is different from CVE-2014-2350.
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. Access to privileged operations on the maintenance port TELNET interface (23/TCP) on M-series and SIS (CSLS/LSNB/LSNG) nodes is controlled by means of utility passwords. These passwords are generated using a deterministic, insecure algorithm using a single seed value composed of a day/hour/minute timestamp with less than 16 bits of entropy. The seed value is fed through a lookup table and a series of permutation operations resulting in three different four-character passwords corresponding to different privilege levels. An attacker can easily reconstruct these passwords and thus gain access to privileged maintenance operations. NOTE: this is different from CVE-2014-2350.
Missing DLLs, if replaced by an insider, could allow an attacker to achieve local privilege escalation on the DeltaV Distributed Control System Controllers and Workstations (All versions) when some DeltaV services are started.
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access.
Emerson Rosemount X-STREAM Gas AnalyzerX-STREAM enhanced XEGP, XEGK, XEFD, XEXF – all revisions, The affected products are vulnerable to improper authentication for accessing log and backup data, which could allow an attacker with a specially crafted URL to obtain access to sensitive information.
In Emerson ValveLink v12.0.264 to v13.4.118, a vulnerability in the ValveLink software may allow a local, unprivileged, trusted insider to escalate privileges due to insecure configuration parameters.
GE PACSystems RX3i CPE100/115: All versions prior to R9.85,CPE302/305/310/330/400/410: All versions prior to R9.90,CRU/320 All versions(End of Life) may allow an attacker sending specially manipulated packets to cause the module state to change to halt-mode, resulting in a denial-of-service condition. An operator must reboot the CPU module after removing battery or energy pack to recover from halt-mode.
A specially crafted script could bypass the authentication of a maintenance port of Emerson DeltaV DCS Versions 11.3.1, 11.3.2, 12.3.1, 13.3.1, 14.3, R5.1, R6 and prior, which may allow an attacker to cause a denial of service.
Emerson DeltaV DCS versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, R5 may allow non-administrative users to change executable and library files on the affected products.
Emerson DeltaV DCS versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, R5 allow a specially crafted DLL file to be placed in the search path and loaded as an internal and valid DLL, which may allow arbitrary code execution.
DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable to a buffer overflow exploit through an open communication port to allow arbitrary code execution.
DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable due to improper path validation which may allow an attacker to replace executable files.